Operation procedure of BA-2S aseptic tapping homogenizer
Operation procedure of BA-2S aseptic tapping homogenizer
1. Connect the power cable to the socket behind the BA-2S aseptic tapping homogenizer and plug it into the external output power socket, turn on the power switch, the LCD display shows the factory setting, BA-2S aseptic tapping homogenizer automatically In standby mode.
2. Check and confirm the groove along the lower edge of the aseptic homogenizer door. If it is buckled on the crossbar at the bottom of the homogenizer, turn the door handle to open the door to the maximum. The homogenized bag containing the sample and the solvent is placed in the homogenizing box, the lower edge of the homogenizing bag is not lower than the hammering plate, the edge of the homogenizing bag mouth is exposed, the door cover is not wrinkled, and then the door switch is turned, After hearing the “drop†sound (the LCD screen should display “Closeâ€), the door is closed. At this time, the door and the upper rail are squeezed to clamp the homogenized bag to seal it.
3. Hold the upper edge of the homogenized bag with your left hand, open the homogenizer door with your right hand, take out the homogenized bag, and finish the work once. If the sample is contaminated, use a special tool to extract the homogenized bag.
4. According to the need to homogenize the sample selection panel speed and timing time, each button will have a "beep" sound prompt. Press the “Settings†setting button. At this time, the number of times of the LCD screen M1 and the number of taps flashes, indicating that the setting state is entered, and the setting button is continuously pressed, the number of taps of M1 - M1 tapping minutes - M1 tapping seconds - M2 tapping times - M2 tapping minutes - M2 tapping seconds - M3 tapping times - M3 tapping minutes - M3 tapping seconds - exiting. When pressing the “Set†button to the parameter to be adjusted, press the increase or decrease button, the parameter will be adjusted accordingly. If you press and hold 1S or longer, the number will increase or decrease continuously. If you want to exit when setting M1, you can Directly "Reset" button to exit. After the setting is completed, press the “Continuous/Cycle†button, M1-M2-M3-Cycle-M1 switches. After adjusting to the required parameters, press the On/Off button, the LCD will work, the machine will run according to the number of times the shot is played and the time will be accumulated in seconds. When the set time is reached, “嘀â€, the LCD display pauses and the machine stops working. Press the on/off button again to run again. If in the loop mode, after the time of running M1, the LCD will automatically display the parameters of M2 and run the parameters of M2. After running the parameters of M3, the long sound of “嘀---†will display pause. The sterile homogenizer stops working. During the running process, there is a door opening action, the liquid crystal display opens the door, and enters a pause state. After closing the door, you need to press the “on/off†button again to start working. In the pause state, long press the reset button 1S or more, “嘀--†long sound, the running time will be “returned to 0â€.
5. For safety reasons, all operating procedures are locked and automatically stopped when the flap door is opened. The sterile homogenizer door is opened during operation, and the BA-2S aseptic tapping homogenizer automatically stops working and the LCD screen displays the current status to prevent pinching the finger.
6. During the work, if you need to pause or terminate the operation midway, you can press the “On/Off†button (the LCD screen should display the current status), and the hammer plate will stop working.